كتيب المصنع
لمزيد من المعلومات حول المصنع وجميع منتجاتنا. يرجى تحميل ملف التعريف الخاص بنا. على هذا الرابط
Polymer Modified Bitumen 70-10
لا تزال المقالة تحت الإنشاء ...
Polymer Modified Bitumen 76-10
لا تزال المقالة تحت الإنشاء ...
Polymer Modified Bitumen 82-10
لا تزال المقالة تحت الإنشاء ...
ASPHALT MC-1
تحضر مادة MC-1 بإضافة مذيبات مناسبة الى الأسفلت الخام ليطابق المواصفات العالمية ASTM D-2027 . و تعرف مادة MC-1 على أنها أسفلت مخفف متوسط الجفاف و تحدد بواسطة اللزوجة
الإستخدامات:
- Treatment of road surfaces and pavement as a prime coat.
- Construction works, protective, and dam proofing coating, foundation, concrete, metal-timer etc.
- Soil stabilization.

جدول البيانات
DESCRIPTION |
ASTM SPECIFIC. |
TEST METHOD |
|
---|---|---|---|
MIN |
MAX |
||
KINEMATIC VISCOSITY AT 60 °C. cSt |
70 |
140 |
ASTM D- 2170 |
FLASH POINT (TAG OPEN CUP) °C |
66 |
– |
ASTM D3143 |
DISTILLATE TEST DISTILLATE VOLUME PERCENT OF TOTAL DISTILLATE TO 680 °F. (360’C) |
|
|
|
a. TO 437 °F. (225 °C.)b. TO 500 °F. (260 °C.)c. TO 600 °F. (316 °C.) |
– 20 65 |
20 60 90 |
ASTM D – 402 |
RESIDUE FORM DISTILLATION TO 680°F.(360 °C.) |
55 |
– |
|
TEST ON RESIDUE FROM DISTILLATION. |
|
|
|
a. VISCOSITY AT 140 °F. (60 °C.)b. DUCTILITY AT 77 °F. (25 °C.)c. SOLUBILITY IN TRICHLOROETHYLENE %WATER % |
300 100 – – |
1200 – – 0.2 |
D – 2170 D – 113 D – 2042 D – 95 |
يوجد لدينا فريق فني متاح لأي نوع من الإستشارات أو الدعم والتوضيح
من على هذا الرابط
ASPHALT MC-70
تحضر مادة MC-70 بإضافة مذيبات مناسبة إلى الأسفلت الخام ليطابق المواصفات العالمية ASTM D-2027 . و تعرف مادة MC-70 على أنها أسفلت مخفف متوسط الجفاف و تحدد بواسطة اللزوجة
الإستخدامات:
- Treatment of road surfaces and pavement as a prime coat.
- Construction works, protective, and dam proofing coating, foundation, concrete, metal-timer etc.
- Soil stabilization.

جدول البيانات
Max. | Min. | AASHTO – Test method | Description |
---|---|---|---|
27 | T – 79 | Flashpoint (open-cup) degrees C | |
120 | 60 | T – 72 | Furol Viscosity at 50 degrees C, sec |
|
10 50 70 85 55 |
T – 78 |
Distillation ( percent of total distillate at 360 degrees C )
To 225 degrees C To 225 degrees C To 260 degrees C To 316 degrees C Residue from to 360 degrees C volume percentage of sample by difference |
Tests on residue from distillation | |||
2400 | 600 | T – 202 | Absolute viscosity at 60 C , poises |
100 | T – 51 | Ductility at 25 degrees C , cm | |
99 | T – 44 | Solubility in Trichloroethylene, percent |
يوجد لدينا فريق فني متاح لأي نوع من الإستشارات أو الدعم والتوضيح
من على هذا الرابط
BITUMEN RC-70
تحضر مادة RC-70 بإضافة مذيبات مناسبة الى الأسفلت الخام ليطابق المواصفات العالمية ASTM D-2027 . و تعرف مادة RC-70 على أنها أسفلت مخفف سريع الجفاف و تحدد بواسطة اللزوجة
الإستخدامات:
- Treatment of road surfaces and pavement as a prime coat.
- Construction works, protective, and dam proofing coating, foundation, concrete, metal-timer etc.
- Soil stabilization.

جدول البيانات
Max. | Min. | AASHTO – Test method | Description |
---|---|---|---|
27 | T – 79 | Flash point (open-cup) degrees C | |
120 | 60 | T – 72 | Furol Viscosity at 50 degrees C, sec |
10 50 70 85 55 |
T – 78 | Distillation ( percent of total distillate at 360 degrees C )
To 225 degrees C To 225 degrees C To 260 degrees C To 316 degrees C Residue from to 360 degrees C volume percentage of sample by difference |
|
Tests on residue from distillation
|
|||
2400 | 600 | T – 202 | Absolute viscosity at 60 C , poises |
100 | T – 51 | Ductility at 25 degrees C , cm | |
99 | T – 44 | Solubility in Trichloroethylene, percent |
يوجد لدينا فريق فني متاح لأي نوع من الإستشارات أو الدعم والتوضيح
من على هذا الرابط
BITUMEN RC-2
تحضر مادة RC-2 بإضافة مذيبات مناسبة الى الأسفلت الخام ليطابق المواصفات العالمية ASTM D-2027 . و تعرف مادة RC-2 على أنها أسفلت مخفف سريع الجفاف و تحدد بواسطة اللزوجة
الإستخدامات:
- Treatment of road surfaces and pavement as a prime coat.
- Construction works, protective, and dam proofing coating, foundation, concrete, metal-timer etc.
- Soil stabilization.

جدول البيانات
Max. | Min. | AASHTOTest method | Description |
---|---|---|---|
27 | T – 79 | Flash point (open-cup) degrees C | |
200 | 100 | T – 72 | Furol Viscosity at 60 degrees C, sec |
|
40 65 87 67 |
T – 78 |
Distillation ( percent of total distillate at 360 degrees C )
To 190 degrees C To 225 degrees C To 316 degrees C Residue from to 360 degrees C volume percentage of sample by difference |
Tests on residue from distillation | |||
120 | 80 | T – 49 | Penetration at 25 degrees C |
100 | T – 51 | Ductility at 25 degrees C , cm | |
99.5 | T – 44 | Solubility in Trichloroethylene, percent |
يوجد لدينا فريق فني متاح لأي نوع من الإستشارات أو الدعم والتوضيح
من على هذا الرابط
LIQUID ASPHALT
الاسفلت السائل هو طلاء مانع لتسرب المياه و يتم تصنيعه من اسفلت عالي الجودة ويتم مزجه بمذيبات خاصة و يتميز الاسفلت السائل بالمرونة بالاضافة الى عمل طبقة عازلة تقاوم الماء و الملح و تغيرات الطقس .
الإستخدامات:
- Liquid Asphalt is a general purpose waterproofing coating suitable for application to existing roofs, as a re-saturant over built-up roof and for underground concrete foundations or basements.
- Liquid Asphalt can also be used on metal roofs, spouts and gutters.
- Liquid Asphalt should not be used for new roof construction or over modified Bitumen membrane.

جدول البيانات
Property | Typical Value | Test Method |
---|---|---|
Density, at 25 °C, Kg/liter | 0.89 – 0.96 | ASTM D 70
|
Viscosity @ 50 °C., cps | 350 – 700 | Brookfield
|
Softening point base from distillation ,°C.
|
60 – 70
|
ASTM D 36
|
Penetration base from distillation @ 25 °C., dmm
|
25 – 35
|
ASTM D 5
|
Ductility base from distillation, @ 25 °C., cm | 10 (min.) | ASTM D 113
|
Adhesion to dry surfaces
|
Good
|
ASTM D 3409
|
Adhesion to wet surfaces | Good | ASTM D 3409
|
Non-Volatile, % Wt. | 55 (min.) | ASTM D 402 |
Volatile, % Wt.
|
45 (max.)
|
ASTM D 402
|
Resistance to Sunlight (UV) | Excellent | ASTM G 53
|
Resistance to heat
|
Good
|
ASTM G 53
|
Resistance to water | Good | ASTM G 53
|
Resistance to salt
|
Good
|
Immersion
|
Service Temperature, °C
|
0 to 80
|
–
|
يوجد لدينا فريق فني متاح لأي نوع من الإستشارات أو الدعم والتوضيح
- Liquid asphalt is formulated with a highly ductile and pliable asphalt in order to withstand the normal cycles of expansion and contraction.
- Cures to a tough elastic film, resistant to weather, sun, heat, rain, underground water and salts.
- Resistant to many acids and alkalies.
- Easy to apply and saves labour costs.
- Economical waterproofing coating.
The surface must be thoroughly cleaned, free of dust, dirt, debris, grease and oil. The surface must be dry. If applied over concrete, it must be thoroughly cured. It can be applied by squeegee, spray, brush or rollers.
- Tools : Clean with kerosene.
- Hands : Use a hand cleaner or kerosene followed by soap and water.
Over concrete : 0.5 to 0.7 Ltr/M2
Base complies with ASTM D449, Type II
20-litre pails and 200-litre drums.
Flammable; contains petroleum distillate. Keep away from open fire, sparks or other ignition sources. Wear protective clothing, gloves and goggles.
- Fire Flammable when wet, flash point 40 °C.
- Skin Avoid repeated or prolonged contact; if contact occurs, remove with hand cleaner that removes oil or grease; then clean with soap and water.
- Eyes Contact could cause irritation. If contact occurs, flush with clean water.
- Inhalation Can cause dizziness. Remove to fresh air and if breathing difficulty persists administer oxygen.
من على هذا الرابط
PRIMER D41
ويستعمل في التطبيقات الباردة و من الأغراض الأساسية له دهان الأسقف . و يحضر باستخدام أسفلت عالي المرونة بالإضافة إلى مذيبات بترولية و إضافات خاصة
الإستخدامات:
- Primer D41 roofing primer is a universal primer for concrete, smooth asphalt roofs, brick and metal surfaces. Used as the prime coat before applying any Primer D41 coatings, flashing compounds, patching compounds and modified bitumen membranes.

جدول البيانات
Property | Typical Value | Test Method |
---|---|---|
Density, at 25°C., Kg/liter | 0.86 – 0.89 | ASTM D 70
|
Viscosity, Saybolt furol at 25 °C., seconds
Viscosity at 25 °C, cps |
25 – 125
70 – 150 |
ASTM D 88
Brookfield |
Drying time, to touch at 25 °C, Hr. | 3 | – |
Drying time, through, at 25 °C, Hr. | 24 | – |
Non-volatile, % Wt. | 45 (Min.) | ASTM D 402 |
Volatile, % Wt. | 55 (Max.) | ASTM 0 402 |
Penetration at 25 °C of asphalt from distillation up to 360 °C dmm | 20 – 50 | ASTM D 5 |
Water content | Nil | ASTM D 95 |
Shelf life | 2 years | MIOM |
يوجد لدينا فريق فني متاح لأي نوع من الإستشارات أو الدعم والتوضيح
- Select solvent allows for optimum penetration of Primer D41 into the surface pores, pin holes and cracks.
- The special wetting agent allows for better saturation, dust absorption and adhesion, thereby preparing the surfaces for a permanent and durable bond between the substrate and coating or membrane.
- When applied over weathered asphalt, it rejuvenates and revitalizes the existing cracked and brittle surfaces, thus preparing them suitably for initiating any maintenance or repair operation.
The surface must be thoroughly cleaned, and all dust, dirt, loose coating, oil and grease removed; concrete must be thoroughly cured, and dried before priming. Before application of subsequent layers, Primer D41 should be allowed to dry.
It can be applied with a roofing brush, roller, squeegee, or airless spray equipment at the recommended coverage rates.
- Tools : Clean with kerosene.
- Hands : Use a hand cleaner or kerosene followed by soap and water.
- Metal : 0.15-0.25 L/M2
- Concrete smooth asphalt : 0.20-0.30 L/M2
- Mineral granule surfaces : 0.30-0.50 L/M2
- Coarse aggregate : 0.80-1.00 L/M2
Complies with ASTM D 41.
18-litre pails and 200-litre drums.
Contains petroleum distillate; flammable; keep away from open fire, sparks or other ignition sources. Wear protective clothing, gloves, and goggles.
- Fire Flammable when wet, flash point 40 °C.
- Skin Avoid repeated or prolonged contact; if contact occurs, remove with hand cleaner that removes oil or grease; then clean with soap and water.
- Eyes Contact could cause irritation. If contact occurs, flush with clean water.
- Inhalation Can cause dizziness. Remove to fresh air and if breathing difficulty persists administer oxygen.
من على هذا الرابط
OXIDIZED ASPHALT 115/15
الاسفلت المؤكسد : و يتم تصنيعه من الاسفلت الخام عن طريق معالجة البيتومين بطرق خاصة ليطابق المواصفات المطلوبة
الإستخدامات:
- Used for protection of underground concrete, bridges, culverts, retaining walls, tanks surroundings, dams, conduits, decks, etc.
- OXIDIZED ASPHALT, type v (grade 115/15) has good resistance for vertical & sloped surfaces under direct sunlight in the temperatures exceeding 500 C.
- Grade 115/15 asphalt can be used in building up waterproofing system.
- Also used as raw material for manufacturing of waterproofing.
- As a mop coat for damp proofing.
- As a crack filler in black top surfaces.
- Excellent bond & adhesion.

جدول البيانات
PROPERTIES | MIN | MAX | TEST METHOD |
---|---|---|---|
SOFTENING POINT — °C | 110 | 120 | ASTM D – 36 |
FLASH POINT — °C | 225 | – | ASTM D – 92 |
PENETRATION @ 0 °C
25 °C, mm/10 46 °C |
–
10 – |
–
20 75 |
ASTM D – 5 |
DUCTILITY AT 25 ° C — cm | – | – | ASTM D – 113 |
SOLUBILITY IN TRICHLOROETHYLENE % | – | – | ASTM D – 2042 |
SPECIFIC GRAVITY | 1.00 | 1.10 | ASTM D – 70 |
يوجد لدينا فريق فني متاح لأي نوع من الإستشارات أو الدعم والتوضيح
Indefinite life in closed drums.
The surface should be clean dry & free from dirt, dust, oil and grease.
Hot applied using a trowel, stiff brush or a mop.
Oxidized asphalt grade 115/15 is packed in 200 kgs drum and in polyamide bags of 25kg.
The rate of application will depend on engineers. Requirement and may vary from project to project. As a general rule two coats are applied consuming 1 kg per so. M. Per coat.
- Care should be taken while heating & handling during application. Strictly recommended to use protective clothing. Gloves, masks, goggles, etc.
- In the event of contact with hot oxidized asphalt on the skin, immediately apply ice or cold water at first instance followed by seeking medical advice.
- Oxidized asphalt is a non-flammable & non-hazardous item.
من على هذا الرابط